Single side opening Bi-parting opening
Leaf thickness (mm) 30
Sliding leaf width minimum - maxiumum (mm) 745 – 2040 745 – 1475
Height of sliding leaf minimum - maxiumum (mm) 2100 – 3000 2100 – 3000
Fixed leaf width minimum - maxiumum (mm) 747 – 2042 692 – 1472
Height of fixed leaf minimum - maxiumum (mm) 2100 – 3000 2100 – 3000
PL without fixed min. - max. (mm) 705 - 2000 1300 - 2760
PL with fixed min. - max. (mm) 710 - 2005 1310 - 2765
HL without fixed min. - max. (mm) 2100 – 3000
HL with fixed min. - max. (mm) 2100 – 3000
Type of glazing Laminated glass 44.4 (thickness 9.5 mm)
Glazing class UNE-EN 356 Class P4A
Cylinder European multipoint profile
Digit 7 (UNE EN 1303) = 6
Digit 8 (UNE EN 1303) = D
Lock Motorised lock with 3 locking points
Burglary resistance.
Requirements and classification
Grade RC2

Applicable
legislation

Burglary resistance.
Requirements and classification
UNE-EN 1627:2021
Building hardware.
Cylinders for locks
UNE-EN 1303:2016
Building glass. Safety glass. Testing and classification of resistance to manual attack. UNE-EN 356:2001
Automatic pedestrian doors.
Safety in use
EN 16005:2013

Which model to choose?

Bi-parting without fixed leaves
Bi-parting with fixed leaves
Single slide without fixed leaves
Single slide with fixed leaves

Visio+ 125

Burglar resistance automatic door RC2 incorporates the Visio+ 125 operator which is characterised by its Inverter technology and its design, as well as its versatility, flexibility and security. It stands out for being one of the operators with the fastest opening speed on the market with a refined and compact design, customisable in a wide variety of finishes. It incorporates IoT technology, which allows connectivity control and remote control of the door.

Learn more about our operators

'Exit only' mode: comfortably secure.

Static load

In this test, loads are applied to different points of the door by means of a hydraulic ram

Dynamic load

In this test, impacts are made against the glass at different points: 3 impacts at the centre and 1 at each corner.
Mass of the impact body: 50 Kg
Drop height: 450 mm

Manual breakout tests